PRODUCTSHose
KanaVapor (ST120 VP)


SPECIFICATIONS
- Gasoline vapor recovery hose
- Temp. Range: -40°F to 140°F
- Applications: Gasoline vapor recovery only
- Construction: Nitrile rubber, rigid PVC helix, smooth bore, corrugated O.D., static grounding wire
- Note: Static wire must be properly imbedded during fitting installation and tested to assure proper static grounding of hose to a grounded system
AVAILABLE SIZES
Inside Dia. | Outside Dia. | Pitch | Minimum Bend Radius |
Working Pressure |
Vacuum Rating |
Weight | Standard Length |
---|---|---|---|---|---|---|---|
Inches | Inches | Inches | 72°F, Inches | 72°F, P.S.I. | 72°F, In Hg | Lbs/Ft | Ft |
2 | 2.36 | 0.39 | 3.0 | 20 | 29.8 | 0.61 | 60, 100 |
3 | 3.46 | 0.59 | 3.5 | 10 | 29.8 | 1.00 | 60, 100 |
4 | 4.57 | 0.65 | 5.0 | 10 | 29.8 | 1.70 | 60, 100 |
*Over flexing or repeated flexing of hose within 18″ of fitting is a common cause of hose failure. Installing a 12″-14″ section of our Banding Coil at the end of the hose should be considered. Kanaflex will not be responsible for damage to hose due to over flexing.